[발표논문] A study on the verification of the exposure system and the SAR values of the exposed cells in

A
study on the verification of the exposure system and the SAR values of the
exposed cells in in vitro experiments



 



Jaesung
Lee*, Hyungsang Ahn*, Junoh An*, Sangbong Jeon**, Jeongki Pack***



*Institute
for Future Radio Engineering



**
Electronics and Telecommunications Research Institute



***Chungnam
National University



 



 



Summary



This study was
conducted to verify the SAR values of the exposed cells in an in vitro experiment. In this study, the
signal output power and the temperature change in the Petri Dish were measured,
and the exposure level of the electromagnetic wave was derived based on the
measurement data. The results show that power of 3.09W is estimated as the
appropriate source input for 1W/kg of 1g-averaged SAR and 24.72W for 8W/kg of
1g-averaged SAR.